Which extinguisher is suitable for a fire in energized electrical equipment?
- Carbon dioxide
- Plain water
- Water-based foam
- Soda-acid
Show the answer
A. Carbon dioxide
Carbon dioxide does not conduct electricity and leaves no residue, so it suits Class C fires. Water and water-based agents conduct current and put the operator at risk of shock.
Reference: FAA-H-8083-30, Safety, Ground Operations and Servicing (fire protection; extinguishing agents)
What must be done before the fuel cap is removed for overwing fueling?
- Turn on the aircraft battery
- Bond the nozzle to the aircraft
- Start the auxiliary power unit
- Disconnect the ground cable
Show the answer
B. Bond the nozzle to the aircraft
Fuel moving through a hose builds a static charge, so the truck, aircraft and nozzle are bonded before the tank is opened to prevent a spark at the filler. Electrical power is kept off as far as practical during fueling.
Reference: FAA-H-8083-30, Safety, Ground Operations and Servicing (fueling procedures)
What must be kept away from oxygen servicing equipment and fittings?
- Dry nitrogen
- Clean water
- Oil and grease
- Teflon tape
Show the answer
C. Oil and grease
Petroleum products can ignite spontaneously in contact with high-pressure oxygen, so hands, tools and fittings must be free of oil and grease. Only approved oxygen-compatible thread sealants and leak-test solutions are used.
Reference: FAA-H-8083-30, Safety, Ground Operations and Servicing (oxygen servicing)